cmPhyIfTxBufferSize

  • 1.3.6.1.4.1.9.10.69.1.1.1.1.9
  • Access readwrite
  • Type Unknown
  • Unit bytes

This object applies when circuit emulation of the client protocol is used. It allows the management client to configure the size of the transmit buffer on the client port. A value of 0 implies that this object does not apply to this interface. Controlling the size of the transmit buffer on a client port may be essential in scenarios where packet streams from various client ports are aggregated onto a single trunk port. The latency associated with an elementary stream received on a client port, from the trunk port is influenced by the nature of other elementary streams in the aggregate. For example, a giant packet in one stream will increase latency in processing packets in other elementary streams. The size of the transmit buffer on the client port must be configured proportional to this expected latency. Increasing the buffer size when latency is higher helps in reassembly of fragmented packets before transmitting them to the client device. Note that increasing the buffer size results in higher latency even when the elementary packet stream is not subject to high jitters. Refer to the platform specific documentation for guidelines on configuring this buffer size.

This OID is also declared by other modules: CISCO-METRO-PHY-MIB

Table columns

27 objects
Oid Name Access Type
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.12 cmPhyIfRate readwrite CmRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.13 cmPhyIfNegotiatedRate readonly CmNegotiatedRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.14 cmPhyIfOverSubscription readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.15 cmPhyIfClientSubrate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.16 cmPhyIfClientSubrateLock readwrite TruthValue

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.10.69.3.2.8 cmPhyIfTxBufferSizeGroup

Comments