cmPhyIfOFC

  • 1.3.6.1.4.1.9.10.69.1.1.1.1.6
  • Access readwrite
  • Type TruthValue

This object allows the management client to enable OFC(Open Fibre Control) safety protocol for the client side interfaces, by writing a 'true' value to this object. A 'false' value would disable OFC. The default value of this object varies depending on the value of cmPhyIfProtocol and cmPhyIfClockRate. When cmPhyIfProtocol or cmPhyIfClockRate is reset, then the value of this object is automatically reset to the default value for that protocol or rate. If non-default OFC behavior is desired, then this object should be set after cmPhyIfProtocol or cmPhyIfClockRate has been reset. This object is not applicable to trunk side interfaces.

This OID is also declared by other modules: CISCO-METRO-PHY-MIB

Table columns

27 objects
Oid Name Access Type
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.12 cmPhyIfRate readwrite CmRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.13 cmPhyIfNegotiatedRate readonly CmNegotiatedRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.14 cmPhyIfOverSubscription readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.15 cmPhyIfClientSubrate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.16 cmPhyIfClientSubrateLock readwrite TruthValue

Used by conformance groups

2 objects
  • 1.3.6.1.4.1.9.10.69.3.2.1 cmPhyIfGroup
  • 1.3.6.1.4.1.9.10.69.3.2.4 cmPhyIf2Group

Comments