cmPhyIfProtocol

  • 1.3.6.1.4.1.9.10.69.1.1.1.1.2
  • Access readwrite
  • Type ProtocolType

This object is used to specify the protocol of the data carried over the client side interface. This object applies to linecards which support a variety of protocols and allow dynamic configuration of the specific protocol to be monitored on the interface. The ifType value for such interfaces remains fixed. The agent may use this object to identify the protocol to be monitored (see the cmPhyIfMonitor object), to set the clock rate for the interface (see the cmPhyIfClockRate object), or to enable or disable functionality related to the protocol, for example OFC (see the cmPhyIfOFC object). The value of this object cannot be modified when the cmPhyIfMonitor object is set to 'true' for that interface. Also, this object does not apply to the trunk side interfaces.

This OID is also declared by other modules: CISCO-METRO-PHY-MIB

Details

Possible values
1 other
2 unknown
3 gigabitEthernet
4 tenGigabitEthernet
5 fibreChannel
6 ficon
7 escon
8 sonet
9 sdh
10 sysplexIscCompatibility
11 sysplexIscPeer
12 sysplexTimerEtr
13 sysplexTimerClo
14 fastEthernet
15 fddi
16 e1
17 t1
18 e3
19 t3
20 dvb
21 sdi
22 its

Table columns

27 objects
Oid Name Access Type
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.12 cmPhyIfRate readwrite CmRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.13 cmPhyIfNegotiatedRate readonly CmNegotiatedRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.14 cmPhyIfOverSubscription readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.15 cmPhyIfClientSubrate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.16 cmPhyIfClientSubrateLock readwrite TruthValue

Used by conformance groups

2 objects
  • 1.3.6.1.4.1.9.10.69.3.2.1 cmPhyIfGroup
  • 1.3.6.1.4.1.9.10.69.3.2.4 cmPhyIf2Group

Comments