cmPhyIfMonitor

  • 1.3.6.1.4.1.9.10.69.1.1.1.1.4
  • Access readwrite
  • Type TruthValue

This object allows the management client to enable monitoring of the error counters on an interface, by writing a value of 'true' to this object. To bypass the monitoring hardware, a value of 'false' must be written to this object. Monitoring does not apply when the value of cmPhyIfProtocol is 'unknown'.

This OID is also declared by other modules: CISCO-METRO-PHY-MIB

Table columns

27 objects
Oid Name Access Type
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.1 cmPhyIfMode readwrite mode2R(1), mode3R(2)
1.3.6.1.4.1.9.10.69.1.1.1.1.2 cmPhyIfProtocol readwrite ProtocolType
1.3.6.1.4.1.9.10.69.1.1.1.1.3 cmPhyIfClockRate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.4 cmPhyIfMonitor readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.5 cmPhyIfLoopback readwrite noLoop(1), diagnosticLoop(2), lineLoop(3), otherLoop(4)
1.3.6.1.4.1.9.10.69.1.1.1.1.6 cmPhyIfOFC readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.7 cmPhyIfLaserSafetyControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.8 cmPhyIfForwardLaserControl readwrite TruthValue
1.3.6.1.4.1.9.10.69.1.1.1.1.9 cmPhyIfTxBufferSize readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.10 cmPhyIfAutoNegotiation readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.11 cmPhyIfTransType readonly TransmissionType
1.3.6.1.4.1.9.10.69.1.1.1.1.12 cmPhyIfRate readwrite CmRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.13 cmPhyIfNegotiatedRate readonly CmNegotiatedRateType
1.3.6.1.4.1.9.10.69.1.1.1.1.14 cmPhyIfOverSubscription readwrite TriValue
1.3.6.1.4.1.9.10.69.1.1.1.1.15 cmPhyIfClientSubrate readwrite Unknown
1.3.6.1.4.1.9.10.69.1.1.1.1.16 cmPhyIfClientSubrateLock readwrite TruthValue

Used by conformance groups

2 objects
  • 1.3.6.1.4.1.9.10.69.3.2.1 cmPhyIfGroup
  • 1.3.6.1.4.1.9.10.69.3.2.4 cmPhyIf2Group