acDs1ConfigLineStatus

  • 1.3.6.1.4.1.2785.2.3.4.1.1.18
  • Access readonly
  • Type Unknown

This variable indicates the Line Status of the interface. It contains loopback, failure, received 'alarm' and transmitted 'alarms information. The acDs1ConfigLineStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) and a LoopbackState simultaneously. acDs1NoAlarm must be set if and only if no other flag is set. If the acDs1loopbackState bit is set, the loopback in effect can be determined from the acDs1loopbackConfig object. The various bit positions are: 1 acDs1NoAlarm No alarm present 2 acDs1RcvFarEndLOF Far end LOF (a.k.a., Yellow Alarm) 4 acDs1XmtFarEndLOF Near end sending LOF Indication 8 acDs1RcvAIS Far end sending AIS 16 acDs1XmtAIS Near end sending AIS 32 acDs1LossOfFrame Near end LOF (a.k.a., Red Alarm) 64 acDs1LossOfSignal Near end Loss Of Signal 128 acDs1LoopbackState Near end is looped 512 acDs1RcvFarEndLOMF Far End Sending TS16 LOMF 1024 acDs1XmtFarEndLOMF Near End Sending TS16 LOMF 2048 acDs1RcvTestCode Near End detects a test code 4096 acDs1RcvFarEndRAI any line status not defined here 8192 acDs1RcvFarEndUnEqp Far End sending VT 1.5 labelled UNEQUIPPED 16384 acDs1NetEquipOOS Carrier Equipment Out of Service

Table columns

30 objects
Oid Name Access Type
1.3.6.1.4.1.2785.2.3.4.1.1.1 acDs1ConfigNodeId notifyonly AcNodeId
1.3.6.1.4.1.2785.2.3.4.1.1.2 acDs1ConfigSlot notifyonly AcSlotNumber
1.3.6.1.4.1.2785.2.3.4.1.1.3 acDs1ConfigPort notifyonly AcPortNumber
1.3.6.1.4.1.2785.2.3.4.1.1.4 acDs1ConfigAdminStatus readwrite AcAdminStatus
1.3.6.1.4.1.2785.2.3.4.1.1.5 acDs1ConfigOpStatus readonly AcOpStatus
1.3.6.1.4.1.2785.2.3.4.1.1.6 acDs1ConfigTimeElapsedInterval readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.7 acDs1ConfigValidIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.8 acDs1ConfigTimeElapsedDay readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.9 acDs1ConfigValidDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.10 acDs1ConfigTimeElapsedFarEndInterval readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.11 acDs1ConfigValidFarEndIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.12 acDs1ConfigTimeElapsedFarEndDay readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.13 acDs1ConfigValidFarEndDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.14 acDs1ConfigLineType readwrite esf(1), d4(2)
1.3.6.1.4.1.2785.2.3.4.1.1.15 acDs1ConfigLineCoding readwrite b8zs(1), ami(2)
1.3.6.1.4.1.2785.2.3.4.1.1.16 acDs1ConfigCircuitIdentifier readwrite Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.17 acDs1ConfigLoopbackConfig readwrite none(1), payload(2), facility(3), other(4), terminal(5), dual(6)
1.3.6.1.4.1.2785.2.3.4.1.1.18 acDs1ConfigLineStatus readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.19 acDs1ConfigSignalMode readonly none(1), message(2), other(3)
1.3.6.1.4.1.2785.2.3.4.1.1.20 acDs1ConfigTransmitClockSource readonly bits(1), local(2), through(3)
1.3.6.1.4.1.2785.2.3.4.1.1.21 acDs1ConfigFdl readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.22 acDs1ConfigInvalidIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.23 acDs1ConfigInvalidDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.24 acDs1ConfigInvalidFarEndIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.25 acDs1ConfigInvalidFarEndDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.26 acDs1ConfigLineStatusLastChange readonly TimeStamp
1.3.6.1.4.1.2785.2.3.4.1.1.27 acDs1ConfigLineStatusChangeTrapEnable readwrite enabled(1), disabled(2)
1.3.6.1.4.1.2785.2.3.4.1.1.28 acDs1ConfigLoopbackStatus readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.29 acDs1ConfigInterfaceName readwrite Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.30 acDs1ConfigTimeSlotIndex readwrite Integer32

Used by notifications

1 objects
  • 1.3.6.1.4.1.2785.2.3.4.0.1 acDs1LineStatusChangeTrap

Comments