acDs1ConfigLineCoding

  • 1.3.6.1.4.1.2785.2.3.4.1.1.15
  • Access readwrite
  • Type b8zs(1), ami(2)
  • Default b8zs

This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. b8zs refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits. ami refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density requirements, such as inverting HDLC data.

Details

Possible values
1 b8zs
2 ami

Table columns

30 objects
Oid Name Access Type
1.3.6.1.4.1.2785.2.3.4.1.1.1 acDs1ConfigNodeId notifyonly AcNodeId
1.3.6.1.4.1.2785.2.3.4.1.1.2 acDs1ConfigSlot notifyonly AcSlotNumber
1.3.6.1.4.1.2785.2.3.4.1.1.3 acDs1ConfigPort notifyonly AcPortNumber
1.3.6.1.4.1.2785.2.3.4.1.1.4 acDs1ConfigAdminStatus readwrite AcAdminStatus
1.3.6.1.4.1.2785.2.3.4.1.1.5 acDs1ConfigOpStatus readonly AcOpStatus
1.3.6.1.4.1.2785.2.3.4.1.1.6 acDs1ConfigTimeElapsedInterval readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.7 acDs1ConfigValidIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.8 acDs1ConfigTimeElapsedDay readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.9 acDs1ConfigValidDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.10 acDs1ConfigTimeElapsedFarEndInterval readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.11 acDs1ConfigValidFarEndIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.12 acDs1ConfigTimeElapsedFarEndDay readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.13 acDs1ConfigValidFarEndDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.14 acDs1ConfigLineType readwrite esf(1), d4(2)
1.3.6.1.4.1.2785.2.3.4.1.1.15 acDs1ConfigLineCoding readwrite b8zs(1), ami(2)
1.3.6.1.4.1.2785.2.3.4.1.1.16 acDs1ConfigCircuitIdentifier readwrite Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.17 acDs1ConfigLoopbackConfig readwrite none(1), payload(2), facility(3), other(4), terminal(5), dual(6)
1.3.6.1.4.1.2785.2.3.4.1.1.18 acDs1ConfigLineStatus readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.19 acDs1ConfigSignalMode readonly none(1), message(2), other(3)
1.3.6.1.4.1.2785.2.3.4.1.1.20 acDs1ConfigTransmitClockSource readonly bits(1), local(2), through(3)
1.3.6.1.4.1.2785.2.3.4.1.1.21 acDs1ConfigFdl readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.22 acDs1ConfigInvalidIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.23 acDs1ConfigInvalidDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.24 acDs1ConfigInvalidFarEndIntervals readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.25 acDs1ConfigInvalidFarEndDays readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.26 acDs1ConfigLineStatusLastChange readonly TimeStamp
1.3.6.1.4.1.2785.2.3.4.1.1.27 acDs1ConfigLineStatusChangeTrapEnable readwrite enabled(1), disabled(2)
1.3.6.1.4.1.2785.2.3.4.1.1.28 acDs1ConfigLoopbackStatus readonly Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.29 acDs1ConfigInterfaceName readwrite Unknown
1.3.6.1.4.1.2785.2.3.4.1.1.30 acDs1ConfigTimeSlotIndex readwrite Integer32