sdlcPortAdminSERVLIM

  • 1.3.6.1.2.1.41.1.1.1.1.8
  • Access readwrite
  • Type Integer32
  • Default 20

This object defines the number of times the active poll list will be traversed before polling a station on the slow poll list for a primary, multipoint SDLC port. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary and sdlcPortAdminTopology == multipoint

Table columns

9 objects
Oid Name Access Type
1.3.6.1.2.1.41.1.1.1.1.1 sdlcPortAdminName readwrite Unknown
1.3.6.1.2.1.41.1.1.1.1.2 sdlcPortAdminRole readwrite primary(1), secondary(2), negotiable(3)
1.3.6.1.2.1.41.1.1.1.1.3 sdlcPortAdminType readwrite leased(1), switched(2)
1.3.6.1.2.1.41.1.1.1.1.4 sdlcPortAdminTopology readwrite pointToPoint(1), multipoint(2)
1.3.6.1.2.1.41.1.1.1.1.5 sdlcPortAdminISTATUS readwrite inactive(1), active(2)
1.3.6.1.2.1.41.1.1.1.1.6 sdlcPortAdminACTIVTO readwrite TimeInterval
1.3.6.1.2.1.41.1.1.1.1.7 sdlcPortAdminPAUSE readwrite TimeInterval
1.3.6.1.2.1.41.1.1.1.1.8 sdlcPortAdminSERVLIM readwrite Integer32
1.3.6.1.2.1.41.1.1.1.1.9 sdlcPortAdminSlowPollTimer readwrite TimeInterval

Used by conformance groups

1 objects
  • 1.3.6.1.2.1.41.1.4.2.2.2 sdlcPrimaryMultipointGroup

Comments