sdlcPortAdminPAUSE

  • 1.3.6.1.2.1.41.1.1.1.1.7
  • Access readwrite
  • Type TimeInterval
  • Default 200

This object defines the minimum elapsed time (in 1/100ths of a second) between any two traversals of the poll list for a primary SDLC port. Depending on the implementation, a write operation to this administered value may not take effect until the port is cycled inactive. The object descriptor contains the name of an NCP configuration parameter, PAUSE. Please note that the value of this object represents 1/100ths of a second while the NCP PAUSE is represented in 1/10ths of a second. This object only has meaning for SDLC ports where sdlcPortAdminRole == primary

Table columns

9 objects
Oid Name Access Type
1.3.6.1.2.1.41.1.1.1.1.1 sdlcPortAdminName readwrite Unknown
1.3.6.1.2.1.41.1.1.1.1.2 sdlcPortAdminRole readwrite primary(1), secondary(2), negotiable(3)
1.3.6.1.2.1.41.1.1.1.1.3 sdlcPortAdminType readwrite leased(1), switched(2)
1.3.6.1.2.1.41.1.1.1.1.4 sdlcPortAdminTopology readwrite pointToPoint(1), multipoint(2)
1.3.6.1.2.1.41.1.1.1.1.5 sdlcPortAdminISTATUS readwrite inactive(1), active(2)
1.3.6.1.2.1.41.1.1.1.1.6 sdlcPortAdminACTIVTO readwrite TimeInterval
1.3.6.1.2.1.41.1.1.1.1.7 sdlcPortAdminPAUSE readwrite TimeInterval
1.3.6.1.2.1.41.1.1.1.1.8 sdlcPortAdminSERVLIM readwrite Integer32
1.3.6.1.2.1.41.1.1.1.1.9 sdlcPortAdminSlowPollTimer readwrite TimeInterval

Used by conformance groups

1 objects
  • 1.3.6.1.2.1.41.1.4.2.2.1 sdlcPrimaryGroup

Comments