sdlcPortAdminType

  • 1.3.6.1.2.1.41.1.1.1.1.3
  • Access readwrite
  • Type leased(1), switched(2)
  • Default leased

This parameter defines whether the SDLC port is to connect to a leased or switched line. A write operation to this administrative value shall not take effect until the SDLC port has been cycled inactive.

Details

Possible values
1 leased
2 switched

Table columns

9 objects
Oid Name Access Type
1.3.6.1.2.1.41.1.1.1.1.1 sdlcPortAdminName readwrite Unknown
1.3.6.1.2.1.41.1.1.1.1.2 sdlcPortAdminRole readwrite primary(1), secondary(2), negotiable(3)
1.3.6.1.2.1.41.1.1.1.1.3 sdlcPortAdminType readwrite leased(1), switched(2)
1.3.6.1.2.1.41.1.1.1.1.4 sdlcPortAdminTopology readwrite pointToPoint(1), multipoint(2)
1.3.6.1.2.1.41.1.1.1.1.5 sdlcPortAdminISTATUS readwrite inactive(1), active(2)
1.3.6.1.2.1.41.1.1.1.1.6 sdlcPortAdminACTIVTO readwrite TimeInterval
1.3.6.1.2.1.41.1.1.1.1.7 sdlcPortAdminPAUSE readwrite TimeInterval
1.3.6.1.2.1.41.1.1.1.1.8 sdlcPortAdminSERVLIM readwrite Integer32
1.3.6.1.2.1.41.1.1.1.1.9 sdlcPortAdminSlowPollTimer readwrite TimeInterval

Used by conformance groups

1 objects
  • 1.3.6.1.2.1.41.1.4.2.1.1 sdlcCorePortAdminGroup

Comments