csApsWaitToRestore

  • 1.3.6.1.4.1.9.9.126.1.2.1.1.8
  • Access readwrite
  • Type Unknown
  • Unit minutes

This object contains interval in minutes to wait before attempting to switch back to working line. Not applicable if the line is configured in non-revertive mode, i.e. protection line will continue to be active, even if failures on the working line are cleared. The framer clears the signal-fault and signal-degrade when APS switch occurs. Please refer to 'csApsRevertive' for description of non-revertive.

This OID is also declared by other modules: CISCO-SONET-MIB

Table columns

32 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.126.1.2.1.1.1 csApsWorkingIndex noaccess InterfaceIndex
1.3.6.1.4.1.9.9.126.1.2.1.1.2 csApsProtectionIndex readwrite InterfaceIndex
1.3.6.1.4.1.9.9.126.1.2.1.1.3 csApsEnable readwrite csApsDisabled(1), csApsEnabled(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.4 csApsArchMode readwrite onePlusOne(1), oneToOne(2), anexBOnePlusOne(3), ycableOnePlusOneNok1k2(4), straightOnePlusOneNok1k2(5)
1.3.6.1.4.1.9.9.126.1.2.1.1.5 csApsActiveLine readonly csApsWorkingLine(1), csApsProtectionLine(2), csApsNone(3)
1.3.6.1.4.1.9.9.126.1.2.1.1.6 csApsSigFaultBER readwrite Unknown
1.3.6.1.4.1.9.9.126.1.2.1.1.7 csApsSigDegradeBER readwrite Unknown
1.3.6.1.4.1.9.9.126.1.2.1.1.8 csApsWaitToRestore readwrite Unknown
1.3.6.1.4.1.9.9.126.1.2.1.1.9 csApsDirection readwrite uniDirectional(1), biDirectional(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.10 csApsRevertive readwrite nonrevertive(1), revertive(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.11 csApsDirectionOperational readonly uniDirectional(1), biDirectional(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.12 csApsArchModeOperational readonly onePlusOne(1), oneToOne(2), anexBOnePlusOne(3), ycableOnePlusOneNok1k2(4), straightOnePlusOneNok1k2(5)
1.3.6.1.4.1.9.9.126.1.2.1.1.13 csApsChannelProtocol readwrite bellcore(1), itu(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.14 csApsFailureStatus readonly CsApsLineFailureStatus
1.3.6.1.4.1.9.9.126.1.2.1.1.15 csApsSwitchReason readonly CsApsLineSwitchReason
1.3.6.1.4.1.9.9.126.1.2.1.1.16 csApsPrimarySection readonly workingSection1(1), workingSection2(2), none(3)
1.3.6.1.4.1.9.9.126.1.2.1.1.1 csApsWorkingIndex noaccess InterfaceIndex
1.3.6.1.4.1.9.9.126.1.2.1.1.2 csApsProtectionIndex readwrite InterfaceIndex
1.3.6.1.4.1.9.9.126.1.2.1.1.3 csApsEnable readwrite csApsDisabled(1), csApsEnabled(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.4 csApsArchMode readwrite onePlusOne(1), oneToOne(2), anexBOnePlusOne(3), ycableOnePlusOneNok1k2(4), straightOnePlusOneNok1k2(5)
1.3.6.1.4.1.9.9.126.1.2.1.1.5 csApsActiveLine readonly csApsWorkingLine(1), csApsProtectionLine(2), csApsNone(3)
1.3.6.1.4.1.9.9.126.1.2.1.1.6 csApsSigFaultBER readwrite Unknown
1.3.6.1.4.1.9.9.126.1.2.1.1.7 csApsSigDegradeBER readwrite Unknown
1.3.6.1.4.1.9.9.126.1.2.1.1.8 csApsWaitToRestore readwrite Unknown
1.3.6.1.4.1.9.9.126.1.2.1.1.9 csApsDirection readwrite uniDirectional(1), biDirectional(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.10 csApsRevertive readwrite nonrevertive(1), revertive(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.11 csApsDirectionOperational readonly uniDirectional(1), biDirectional(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.12 csApsArchModeOperational readonly onePlusOne(1), oneToOne(2), anexBOnePlusOne(3), ycableOnePlusOneNok1k2(4), straightOnePlusOneNok1k2(5)
1.3.6.1.4.1.9.9.126.1.2.1.1.13 csApsChannelProtocol readwrite bellcore(1), itu(2)
1.3.6.1.4.1.9.9.126.1.2.1.1.14 csApsFailureStatus readonly CsApsLineFailureStatus
1.3.6.1.4.1.9.9.126.1.2.1.1.15 csApsSwitchReason readonly CsApsLineSwitchReason
1.3.6.1.4.1.9.9.126.1.2.1.1.16 csApsPrimarySection readonly workingSection1(1), workingSection2(2), none(3)

Used by conformance groups

2 objects
  • 1.3.6.1.4.1.9.9.126.3.2.4 ciscoSonetApsMIBGroup
  • 1.3.6.1.4.1.9.9.126.3.2.5 ciscoSonetApsMIBGroup1

Comments