coIfXcvrLSCRestartMode

  • 1.3.6.1.4.1.9.10.66.1.4.1.1.9
  • Access readwrite
  • Type automaticRestart(1), manualRestart(2)

This object selects the mechanism used to restore transmission after the fiber has been repaired or reconnected. 'automaticRestart': This mode selects automatic restart of the laser by periodically transmitting restart pulses. The period between restart pulse transmissions is specified by coIfXcvrLSCPulseReptitionTime. 'manualRestart': This mode selects manual restart of the laser. After the fiber has been repaired or reconnected, the coIfXcvrLSCManualRestart object should be used to trigger transmission of a restart pulse.

This OID is also declared by other modules: CISCO-OPTICAL-IF-EXTN-MIB

Details

Possible values
1 automaticRestart
2 manualRestart

Table columns

26 objects
Oid Name Access Type
1.3.6.1.4.1.9.10.66.1.4.1.1.1 coIfXcvrLaserAdminStatus readwrite up(1), down(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.2 coIfXcvrLaserOperStatus readonly transmitting(1), degraded(2), down(3), lscDown(4), flcDown(5), unknown(6)
1.3.6.1.4.1.9.10.66.1.4.1.1.3 coIfXcvrMinLaserFrequency readwrite CoDwdmFrequencyOrZero
1.3.6.1.4.1.9.10.66.1.4.1.1.4 coIfXcvrLaserFrequencySpacing readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.5 coIfXcvrLaserFrequencyBitmap readonly Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.6 coIfXcvrForwardLaserControl readwrite enable(1), disable(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.7 coIfXcvrLaserSafetyControl readwrite enable(1), disable(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.8 coIfXcvrLSCProtocol readwrite proprietary(1), g664(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.9 coIfXcvrLSCRestartMode readwrite automaticRestart(1), manualRestart(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.10 coIfXcvrLSCManualRestart readwrite noop(1), restart(2), restartForTest(3)
1.3.6.1.4.1.9.10.66.1.4.1.1.11 coIfXcvrLSCPulseLength readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.12 coIfXcvrLSCTestPulseLength readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.13 coIfXcvrLSCPulseRepetitionTime readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.1 coIfXcvrLaserAdminStatus readwrite up(1), down(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.2 coIfXcvrLaserOperStatus readonly transmitting(1), degraded(2), down(3), lscDown(4), flcDown(5), unknown(6)
1.3.6.1.4.1.9.10.66.1.4.1.1.3 coIfXcvrMinLaserFrequency readwrite CoDwdmFrequencyOrZero
1.3.6.1.4.1.9.10.66.1.4.1.1.4 coIfXcvrLaserFrequencySpacing readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.5 coIfXcvrLaserFrequencyBitmap readonly Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.6 coIfXcvrForwardLaserControl readwrite enable(1), disable(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.7 coIfXcvrLaserSafetyControl readwrite enable(1), disable(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.8 coIfXcvrLSCProtocol readwrite proprietary(1), g664(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.9 coIfXcvrLSCRestartMode readwrite automaticRestart(1), manualRestart(2)
1.3.6.1.4.1.9.10.66.1.4.1.1.10 coIfXcvrLSCManualRestart readwrite noop(1), restart(2), restartForTest(3)
1.3.6.1.4.1.9.10.66.1.4.1.1.11 coIfXcvrLSCPulseLength readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.12 coIfXcvrLSCTestPulseLength readwrite Unknown
1.3.6.1.4.1.9.10.66.1.4.1.1.13 coIfXcvrLSCPulseRepetitionTime readwrite Unknown

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.10.66.3.2.6 coIfXcvrLSCMIBGroup

Comments