coIfXcvrForwardLaserControl
This object is used to enable or disable Forward Laser Control (FLC) on this interface. If Forward Laser Control is enabled, the laser is automatically shut down when the receive direction of the cross-connected interface is in an alarm condition.
This OID is also declared by other modules:
CISCO-OPTICAL-IF-EXTN-MIB
Details
Possible values
| 1 | enable |
| 2 | disable |
Table columns
26 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.4.1.9.10.66.1.4.1.1.1 | coIfXcvrLaserAdminStatus | readwrite | up(1), down(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.2 | coIfXcvrLaserOperStatus | readonly | transmitting(1), degraded(2), down(3), lscDown(4), flcDown(5), unknown(6) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.3 | coIfXcvrMinLaserFrequency | readwrite | CoDwdmFrequencyOrZero |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.4 | coIfXcvrLaserFrequencySpacing | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.5 | coIfXcvrLaserFrequencyBitmap | readonly | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.6 | coIfXcvrForwardLaserControl | readwrite | enable(1), disable(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.7 | coIfXcvrLaserSafetyControl | readwrite | enable(1), disable(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.8 | coIfXcvrLSCProtocol | readwrite | proprietary(1), g664(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.9 | coIfXcvrLSCRestartMode | readwrite | automaticRestart(1), manualRestart(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.10 | coIfXcvrLSCManualRestart | readwrite | noop(1), restart(2), restartForTest(3) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.11 | coIfXcvrLSCPulseLength | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.12 | coIfXcvrLSCTestPulseLength | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.13 | coIfXcvrLSCPulseRepetitionTime | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.1 | coIfXcvrLaserAdminStatus | readwrite | up(1), down(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.2 | coIfXcvrLaserOperStatus | readonly | transmitting(1), degraded(2), down(3), lscDown(4), flcDown(5), unknown(6) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.3 | coIfXcvrMinLaserFrequency | readwrite | CoDwdmFrequencyOrZero |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.4 | coIfXcvrLaserFrequencySpacing | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.5 | coIfXcvrLaserFrequencyBitmap | readonly | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.6 | coIfXcvrForwardLaserControl | readwrite | enable(1), disable(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.7 | coIfXcvrLaserSafetyControl | readwrite | enable(1), disable(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.8 | coIfXcvrLSCProtocol | readwrite | proprietary(1), g664(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.9 | coIfXcvrLSCRestartMode | readwrite | automaticRestart(1), manualRestart(2) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.10 | coIfXcvrLSCManualRestart | readwrite | noop(1), restart(2), restartForTest(3) |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.11 | coIfXcvrLSCPulseLength | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.12 | coIfXcvrLSCTestPulseLength | readwrite | Unknown |
| 1.3.6.1.4.1.9.10.66.1.4.1.1.13 | coIfXcvrLSCPulseRepetitionTime | readwrite | Unknown |
Used by conformance groups
1 objects- 1.3.6.1.4.1.9.10.66.3.2.4 coIfXcvrBaseMIBGroup