juniV35IfIgnoreDcd

  • 1.3.6.1.4.1.4874.2.2.59.1.2.1.7
  • Access readwrite
  • Type ignoredNone(0), dcdIgnored(1), linkStateIgnored(2)
  • Default ignoredNone

When in X.21/V.35 DTE mode we have the capability of ignoring the DCD signal in determining whether or not an interface is up.

This OID is also declared by other modules: Unisphere-Data-V35-MIB

Details

Possible values
0 ignoredNone
1 dcdIgnored
2 linkStateIgnored

Table columns

8 objects
Oid Name Access Type
1.3.6.1.4.1.4874.2.2.59.1.2.1.1 juniV35IfIndex noaccess InterfaceIndex
1.3.6.1.4.1.4874.2.2.59.1.2.1.2 juniV35IfType readonly x21(0), v35(1), interfaceTypeNoCable(2)
1.3.6.1.4.1.4874.2.2.59.1.2.1.3 juniV35IfMode readonly dte(0), dce(1), interfaceModeNoCable(2)
1.3.6.1.4.1.4874.2.2.59.1.2.1.4 juniV35IfClockRate readwrite Unsigned32
1.3.6.1.4.1.4874.2.2.59.1.2.1.5 juniV35IfNrzEncoding readwrite normal(0), inverted(1)
1.3.6.1.4.1.4874.2.2.59.1.2.1.6 juniV35IfTxClock readwrite normal(0), inverted(1)
1.3.6.1.4.1.4874.2.2.59.1.2.1.7 juniV35IfIgnoreDcd readwrite ignoredNone(0), dcdIgnored(1), linkStateIgnored(2)
1.3.6.1.4.1.4874.2.2.59.1.2.1.8 juniV35IfLoopback readwrite none(0), loopback(1)

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.4874.2.2.59.4.2.1 juniV35Group