juniV35IfClockRate

  • 1.3.6.1.4.1.4874.2.2.59.1.2.1.4
  • Access readwrite
  • Type Unsigned32
  • Unit hertz
  • Default 2048000

The clock rate setting in hertz for this X.21/V.35 interface. Only the following values are valid: 1200, 2400, 4800, 9600, 19200, 38400, 56000, 64000, 128000, 1024000, 1536000, 2048000, 3072000, 4096000, 4915200, 6144000, and 8192000. If a value other than one of the predefined values is set, then the closest matching value is used. The clock rate parameter is only meaningful when the interface is in DCE mode. When the interface is in DTE mode, the value is simply ignored.

This OID is also declared by other modules: Unisphere-Data-V35-MIB

Table columns

8 objects
Oid Name Access Type
1.3.6.1.4.1.4874.2.2.59.1.2.1.1 juniV35IfIndex noaccess InterfaceIndex
1.3.6.1.4.1.4874.2.2.59.1.2.1.2 juniV35IfType readonly x21(0), v35(1), interfaceTypeNoCable(2)
1.3.6.1.4.1.4874.2.2.59.1.2.1.3 juniV35IfMode readonly dte(0), dce(1), interfaceModeNoCable(2)
1.3.6.1.4.1.4874.2.2.59.1.2.1.4 juniV35IfClockRate readwrite Unsigned32
1.3.6.1.4.1.4874.2.2.59.1.2.1.5 juniV35IfNrzEncoding readwrite normal(0), inverted(1)
1.3.6.1.4.1.4874.2.2.59.1.2.1.6 juniV35IfTxClock readwrite normal(0), inverted(1)
1.3.6.1.4.1.4874.2.2.59.1.2.1.7 juniV35IfIgnoreDcd readwrite ignoredNone(0), dcdIgnored(1), linkStateIgnored(2)
1.3.6.1.4.1.4874.2.2.59.1.2.1.8 juniV35IfLoopback readwrite none(0), loopback(1)

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.4874.2.2.59.4.2.1 juniV35Group

Comments