juniFrCircuitState

  • 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.3
  • Access readwrite
  • Type invalid(1), active(2), inactive(3)
  • Default active

Indicates whether the particular virtual circuit is operational. In the absence of a Data Link Connection Management Interface, virtual circuit entries (rows) may be created by setting virtual circuit state to 'active', or deleted by changing Circuit state to 'invalid'. Whether or not the row actually disappears is left to the implementation, so this object may actually read as 'invalid' for some arbitrary length of time. It is also legal to set the state of a virtual circuit to 'inactive' to temporarily disable a given circuit. The use of 'invalid' is deprecated in this SNMP Version 2 MIB, in favor of juniFrCircuitRowStatus.

This OID is also declared by other modules: Unisphere-Data-FRAME-RELAY-MIB

Details

Possible values
1 invalid
2 active
3 inactive

Table columns

23 objects
Oid Name Access Type
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.1 juniFrCircuitIfIndex noaccess InterfaceIndex
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.2 juniFrCircuitDlci noaccess DLCI
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.3 juniFrCircuitState readwrite invalid(1), active(2), inactive(3)
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.4 juniFrCircuitReceivedFECNs readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.5 juniFrCircuitReceivedBECNs readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.6 juniFrCircuitSentFrames readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.7 juniFrCircuitSentOctets readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.8 juniFrCircuitReceivedFrames readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.9 juniFrCircuitReceivedOctets readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.10 juniFrCircuitCreationTime readonly TimeStamp
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.11 juniFrCircuitLastTimeChange readonly TimeStamp
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.12 juniFrCircuitCommittedBurst readwrite Unknown
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.13 juniFrCircuitExcessBurst readwrite Unknown
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.14 juniFrCircuitThroughput readwrite Unknown
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.15 juniFrCircuitMulticast readwrite unicast(1), oneWay(2), twoWay(3), nWay(4)
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.16 juniFrCircuitType readonly static(1), dynamic(2)
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.17 juniFrCircuitDiscards readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.18 juniFrCircuitReceivedDEs readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.19 juniFrCircuitSentDEs readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.20 juniFrCircuitLogicalIfIndex readwrite InterfaceIndex
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.21 juniFrCircuitRowStatus readwrite RowStatus
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.22 juniFrCircuitSentFECNs readonly Counter32
1.3.6.1.4.1.4874.2.2.10.1.1.4.1.23 juniFrCircuitSentBECNs readonly Counter32

Used by conformance groups

2 objects
  • 1.3.6.1.4.1.4874.2.2.10.4.2.1 juniFrGroup
  • 1.3.6.1.4.1.4874.2.2.10.4.2.3 juniFrGroup2

Comments