cnsT4ClkSrcESMCCap

This object indicates the ESMC capability of an input clock source configured for the T4 clock selection. This is applicable only to Synchronous Ethernet input clock source identified by cnsT4ClkSrcIntfType 'netsyncIfTypeEthernet'.

This OID is also declared by other modules: CISCO-NETSYNC-MIB

Details

Possible values
1 netsyncESMCCapNone
2 netsyncESMCCapTxRx
3 netsyncESMCCapTx
4 netsyncESMCCapRx
5 netsyncESMCCapInvalid

Table columns

38 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.761.1.1.5.1.1 cnsT4ClkSrcNetsyncIndex noaccess Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.2 cnsT4ClkSrcName readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.3 cnsT4ClkSrcIntfType readonly CiscoNetsyncIfType
1.3.6.1.4.1.9.9.761.1.1.5.1.4 cnsT4ClkSrcPriority readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.5 cnsT4ClkSrcESMCCap readonly CiscoNetsyncESMCCap
1.3.6.1.4.1.9.9.761.1.1.5.1.6 cnsT4ClkSrcSSMCap readonly CiscoNetsyncSSMCap
1.3.6.1.4.1.9.9.761.1.1.5.1.7 cnsT4ClkSrcQualityLevelTxCfg readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.8 cnsT4ClkSrcQualityLevelRxCfg readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.9 cnsT4ClkSrcQualityLevelTx readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.10 cnsT4ClkSrcQualityLevelRx readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.11 cnsT4ClkSrcQualityLevel readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.12 cnsT4ClkSrcHoldoffTime readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.13 cnsT4ClkSrcWtrTime readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.14 cnsT4ClkSrcLockout readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.15 cnsT4ClkSrcSignalFailure readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.16 cnsT4ClkSrcAlarm readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.17 cnsT4ClkSrcAlarmInfo readonly CiscoNetsyncAlarmInfo
1.3.6.1.4.1.9.9.761.1.1.5.1.18 cnsT4ClkSrcFSW readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.19 cnsT4ClkSrcMSW readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.1 cnsT4ClkSrcNetsyncIndex noaccess Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.2 cnsT4ClkSrcName readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.3 cnsT4ClkSrcIntfType readonly CiscoNetsyncIfType
1.3.6.1.4.1.9.9.761.1.1.5.1.4 cnsT4ClkSrcPriority readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.5 cnsT4ClkSrcESMCCap readonly CiscoNetsyncESMCCap
1.3.6.1.4.1.9.9.761.1.1.5.1.6 cnsT4ClkSrcSSMCap readonly CiscoNetsyncSSMCap
1.3.6.1.4.1.9.9.761.1.1.5.1.7 cnsT4ClkSrcQualityLevelTxCfg readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.8 cnsT4ClkSrcQualityLevelRxCfg readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.9 cnsT4ClkSrcQualityLevelTx readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.10 cnsT4ClkSrcQualityLevelRx readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.11 cnsT4ClkSrcQualityLevel readonly CiscoNetsyncQualityLevel
1.3.6.1.4.1.9.9.761.1.1.5.1.12 cnsT4ClkSrcHoldoffTime readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.13 cnsT4ClkSrcWtrTime readonly Unknown
1.3.6.1.4.1.9.9.761.1.1.5.1.14 cnsT4ClkSrcLockout readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.15 cnsT4ClkSrcSignalFailure readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.16 cnsT4ClkSrcAlarm readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.17 cnsT4ClkSrcAlarmInfo readonly CiscoNetsyncAlarmInfo
1.3.6.1.4.1.9.9.761.1.1.5.1.18 cnsT4ClkSrcFSW readonly TruthValue
1.3.6.1.4.1.9.9.761.1.1.5.1.19 cnsT4ClkSrcMSW readonly TruthValue

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.9.761.2.2.5 cnsT4ClkSrcObjectGroup

Comments