cfmConditionAlarmActions

  • 1.3.6.1.4.1.9.9.692.1.4.1.1.16
  • Access readonly
  • Type Unknown

This object indicates the actions taken by the device when the alarm condition changes state: 'syslog' The device sends a syslog message. 'snmp' The device sends a cfmNotifyAlarm notification if and only if cfmNotifyEnable is set to 'true'. The value of this column only has relevance if the corresponding instance of cfmConditionAlarm is 'discrete'

This OID is also declared by other modules: CISCO-FLOW-MONITOR-MIB

Table columns

34 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.692.1.4.1.1.1 cfmConditionProfile noaccess FlowMonitorConditionsProfile
1.3.6.1.4.1.9.9.692.1.4.1.1.2 cfmConditionId noaccess FlowMonitorConditionIdentifier
1.3.6.1.4.1.9.9.692.1.4.1.1.3 cfmConditionDescr readonly SnmpAdminString
1.3.6.1.4.1.9.9.692.1.4.1.1.4 cfmConditionMonitoredElement readonly AutonomousType
1.3.6.1.4.1.9.9.692.1.4.1.1.5 cfmConditionType readonly other(1), boolean(2), risingThreshold(3), fallingThreshold(4), risingAndFallingThreshold(5)
1.3.6.1.4.1.9.9.692.1.4.1.1.6 cfmConditionThreshRiseScale readonly FlowMetricScale
1.3.6.1.4.1.9.9.692.1.4.1.1.7 cfmConditionThreshRisePrecision readonly FlowMetricPrecision
1.3.6.1.4.1.9.9.692.1.4.1.1.8 cfmConditionThreshRise readonly FlowMetricValue
1.3.6.1.4.1.9.9.692.1.4.1.1.9 cfmConditionThreshFallScale readonly FlowMetricScale
1.3.6.1.4.1.9.9.692.1.4.1.1.10 cfmConditionThreshFallPrecision readonly FlowMetricPrecision
1.3.6.1.4.1.9.9.692.1.4.1.1.11 cfmConditionThreshFall readonly FlowMetricValue
1.3.6.1.4.1.9.9.692.1.4.1.1.13 cfmConditionSampleType readonly other(1), raw(2), slidingWindowAvg(3), expDecayingAvg(4)
1.3.6.1.4.1.9.9.692.1.4.1.1.14 cfmConditionSampleWindow readonly Unknown
1.3.6.1.4.1.9.9.692.1.4.1.1.15 cfmConditionAlarm readonly none(1), discrete(2), grouped(3)
1.3.6.1.4.1.9.9.692.1.4.1.1.16 cfmConditionAlarmActions readonly Unknown
1.3.6.1.4.1.9.9.692.1.4.1.1.17 cfmConditionAlarmSeverity readonly CiscoAlarmSeverity
1.3.6.1.4.1.9.9.692.1.4.1.1.18 cfmConditionAlarmGroup readonly FlowMonitorAlarmGroupIdentifier
1.3.6.1.4.1.9.9.692.1.4.1.1.1 cfmConditionProfile noaccess FlowMonitorConditionsProfile
1.3.6.1.4.1.9.9.692.1.4.1.1.2 cfmConditionId noaccess FlowMonitorConditionIdentifier
1.3.6.1.4.1.9.9.692.1.4.1.1.3 cfmConditionDescr readonly SnmpAdminString
1.3.6.1.4.1.9.9.692.1.4.1.1.4 cfmConditionMonitoredElement readonly AutonomousType
1.3.6.1.4.1.9.9.692.1.4.1.1.5 cfmConditionType readonly other(1), boolean(2), risingThreshold(3), fallingThreshold(4), risingAndFallingThreshold(5)
1.3.6.1.4.1.9.9.692.1.4.1.1.6 cfmConditionThreshRiseScale readonly FlowMetricScale
1.3.6.1.4.1.9.9.692.1.4.1.1.7 cfmConditionThreshRisePrecision readonly FlowMetricPrecision
1.3.6.1.4.1.9.9.692.1.4.1.1.8 cfmConditionThreshRise readonly FlowMetricValue
1.3.6.1.4.1.9.9.692.1.4.1.1.9 cfmConditionThreshFallScale readonly FlowMetricScale
1.3.6.1.4.1.9.9.692.1.4.1.1.10 cfmConditionThreshFallPrecision readonly FlowMetricPrecision
1.3.6.1.4.1.9.9.692.1.4.1.1.11 cfmConditionThreshFall readonly FlowMetricValue
1.3.6.1.4.1.9.9.692.1.4.1.1.13 cfmConditionSampleType readonly other(1), raw(2), slidingWindowAvg(3), expDecayingAvg(4)
1.3.6.1.4.1.9.9.692.1.4.1.1.14 cfmConditionSampleWindow readonly Unknown
1.3.6.1.4.1.9.9.692.1.4.1.1.15 cfmConditionAlarm readonly none(1), discrete(2), grouped(3)
1.3.6.1.4.1.9.9.692.1.4.1.1.16 cfmConditionAlarmActions readonly Unknown
1.3.6.1.4.1.9.9.692.1.4.1.1.17 cfmConditionAlarmSeverity readonly CiscoAlarmSeverity
1.3.6.1.4.1.9.9.692.1.4.1.1.18 cfmConditionAlarmGroup readonly FlowMonitorAlarmGroupIdentifier

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.9.692.2.2.4 cfmFlowConditionsGroup

Comments