cfmFlowMonitorAlarmSeverity
This object indicates the high severity alarm condition currently raised by the flow monitor and the traffic flows monitored by the flow monitor. If no alarm is raised for the flow monitor and the traffic flows monitored for the flow monitor, then the value of this column is 'cleared'.
This OID is also declared by other modules:
CISCO-FLOW-MONITOR-MIB
Table columns
26 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.4.1.9.9.692.1.1.1.1.1 | cfmFlowMonitorId | noaccess | FlowMonitorIdentifier |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.2 | cfmFlowMonitorDescr | readonly | SnmpAdminString |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.3 | cfmFlowMonitorCaps | readonly | FlowMetrics |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.4 | cfmFlowMonitorFlowCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.5 | cfmFlowMonitorConditionsProfile | readonly | FlowMonitorConditionsProfileOrZero |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.6 | cfmFlowMonitorConditions | readonly | FlowMonitorConditions |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.7 | cfmFlowMonitorAlarms | readonly | FlowMonitorConditions |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.8 | cfmFlowMonitorAlarmSeverity | readonly | CiscoAlarmSeverity |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.9 | cfmFlowMonitorAlarmCriticalCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.10 | cfmFlowMonitorAlarmMajorCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.11 | cfmFlowMonitorAlarmMinorCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.12 | cfmFlowMonitorAlarmWarningCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.13 | cfmFlowMonitorAlarmInfoCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.1 | cfmFlowMonitorId | noaccess | FlowMonitorIdentifier |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.2 | cfmFlowMonitorDescr | readonly | SnmpAdminString |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.3 | cfmFlowMonitorCaps | readonly | FlowMetrics |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.4 | cfmFlowMonitorFlowCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.5 | cfmFlowMonitorConditionsProfile | readonly | FlowMonitorConditionsProfileOrZero |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.6 | cfmFlowMonitorConditions | readonly | FlowMonitorConditions |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.7 | cfmFlowMonitorAlarms | readonly | FlowMonitorConditions |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.8 | cfmFlowMonitorAlarmSeverity | readonly | CiscoAlarmSeverity |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.9 | cfmFlowMonitorAlarmCriticalCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.10 | cfmFlowMonitorAlarmMajorCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.11 | cfmFlowMonitorAlarmMinorCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.12 | cfmFlowMonitorAlarmWarningCount | readonly | Gauge32 |
| 1.3.6.1.4.1.9.9.692.1.1.1.1.13 | cfmFlowMonitorAlarmInfoCount | readonly | Gauge32 |
Used by conformance groups
1 objects- 1.3.6.1.4.1.9.9.692.2.2.1 cfmFlowMonitorGroup