clMeshNodeBatteryChargingState
This object represents the charging status of the battery. unknown - Charging state is unknown, disabled - Charging is disabled, charging - Battery is charging, discharging - Battery is discharging, charged - Battery is charged
Details
Possible values
| 1 | unknown |
| 2 | disabled |
| 3 | charging |
| 4 | discharging |
| 5 | charged |
Table columns
13 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.4.1.9.9.620.1.1.1.1.1 | clMeshNodeBatteryModelName | readonly | Unknown |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.2 | clMeshNodeBatteryStatus | readonly | unknown(1), normal(2), overloaded(3), low(4), acfail(5), replace(6), missing(7) |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.3 | clMeshNodeBatteryChargingState | readonly | unknown(1), disabled(2), charging(3), discharging(4), charged(5) |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.4 | clMeshNodeBatteryChargingLevel | readonly | Integer32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.5 | clMeshNodeBatteryRemainingCapacity | readonly | Unsigned32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.6 | clMeshNodeBatterySwVersion | readonly | Unknown |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.7 | clMeshNodeBatterySerialNumber | readonly | Unknown |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.8 | clMeshNodeBatteryInputVoltage | readonly | Unsigned32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.9 | clMeshNodeBatteryOutputVoltage | readonly | Unsigned32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.10 | clMeshNodeBatteryOutputPower | readonly | Unsigned32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.11 | clMeshNodeBatteryInternalVoltage | readonly | Unsigned32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.12 | clMeshNodeBatteryTemperature | readonly | Integer32 |
| 1.3.6.1.4.1.9.9.620.1.1.1.1.13 | clMeshNodeBatteryCurrent | readonly | Unsigned32 |
Used by conformance groups
1 objects- 1.3.6.1.4.1.9.9.620.2.2.1 ciscoLwappMeshBatteryInfoGroup