cmShutdown

  • 1.3.6.1.4.1.9.9.47.1.3.2.1.4
  • Access readwrite
  • Type TruthValue
  • Default false

This object is used to put modem out of service, i.e. modem cannot make calls or answer calls. This is a hard busyout command to bring the modem out of service immediately without waiting for the call to be ended normally. After modem is shutdown, the following commands can be applied to those modems - reset, bad modem, download modem firmware, etc. The value of true(1) indicates the hard busyout has been issued to the modem. The value of false(2) indicates the modem has not been hard busyout.

This OID is also declared by other modules: CISCO-MODEM-MGMT-MIB

Table columns

12 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.47.1.3.2.1.1 cmATModePermit readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.1 cmATModePermit readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.2 cmStatusPolling readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.2 cmStatusPolling readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.3 cmBusyOutRequest readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.3 cmBusyOutRequest readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.4 cmShutdown readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.4 cmShutdown readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.5 cmHoldReset readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.5 cmHoldReset readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.6 cmBad readwrite TruthValue
1.3.6.1.4.1.9.9.47.1.3.2.1.6 cmBad readwrite TruthValue

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.9.47.3.2.3 cmLineInfoGroup

Comments