fcPingTrapOnCompletion

  • 1.3.6.1.4.1.9.9.295.1.1.1.1.13
  • Access readwrite
  • Type TruthValue
  • Default false

This specifies if fcPingCompletionNotify notification should be generated or not when the corresponding ping sequence completes. If this object is set to 'true', then the notification is generated. If this object is set to 'false', then the notification is not generated. This object cannot be modified if the corresponding instance of fcPingOperStatus object has a value of 'inProgress'.

This OID is also declared by other modules: CISCO-FCPING-MIB

Table columns

28 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.295.1.1.1.1.1 fcPingIndex noaccess Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.2 fcPingVsanIndex readwrite VsanIndex
1.3.6.1.4.1.9.9.295.1.1.1.1.3 fcPingAddressType readwrite FcAddressType
1.3.6.1.4.1.9.9.295.1.1.1.1.4 fcPingAddress readwrite FcAddress
1.3.6.1.4.1.9.9.295.1.1.1.1.5 fcPingPacketCount readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.6 fcPingPayloadSize readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.7 fcPingPacketTimeout readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.8 fcPingDelay readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.9 fcPingAgeInterval readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.10 fcPingUsrPriority readwrite high(1), low(2)
1.3.6.1.4.1.9.9.295.1.1.1.1.11 fcPingAdminStatus readwrite FcStartOper
1.3.6.1.4.1.9.9.295.1.1.1.1.12 fcPingOperStatus readonly inProgress(1), complete(2), disabled(3), failure(4)
1.3.6.1.4.1.9.9.295.1.1.1.1.13 fcPingTrapOnCompletion readwrite TruthValue
1.3.6.1.4.1.9.9.295.1.1.1.1.14 fcPingRowStatus readwrite RowStatus
1.3.6.1.4.1.9.9.295.1.1.1.1.1 fcPingIndex noaccess Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.2 fcPingVsanIndex readwrite VsanIndex
1.3.6.1.4.1.9.9.295.1.1.1.1.3 fcPingAddressType readwrite FcAddressType
1.3.6.1.4.1.9.9.295.1.1.1.1.4 fcPingAddress readwrite FcAddress
1.3.6.1.4.1.9.9.295.1.1.1.1.5 fcPingPacketCount readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.6 fcPingPayloadSize readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.7 fcPingPacketTimeout readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.8 fcPingDelay readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.9 fcPingAgeInterval readwrite Unknown
1.3.6.1.4.1.9.9.295.1.1.1.1.10 fcPingUsrPriority readwrite high(1), low(2)
1.3.6.1.4.1.9.9.295.1.1.1.1.11 fcPingAdminStatus readwrite FcStartOper
1.3.6.1.4.1.9.9.295.1.1.1.1.12 fcPingOperStatus readonly inProgress(1), complete(2), disabled(3), failure(4)
1.3.6.1.4.1.9.9.295.1.1.1.1.13 fcPingTrapOnCompletion readwrite TruthValue
1.3.6.1.4.1.9.9.295.1.1.1.1.14 fcPingRowStatus readwrite RowStatus

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.9.295.2.2.1 fcPingConfigGroup