vsanFcTimerEdtov

  • 1.3.6.1.4.1.9.9.282.1.4.8.1.3
  • Access readwrite
  • Type Unknown
  • Unit msec
  • Default 2000

The Error_Detect_Timeout Value used for FxPorts as the timeout value for detecting an error condition. Note that all switches in a VSAN should be configured with the same value of this timeout. Note that value of this object must be less than value of vsanFcTimerDstov. If the corresponding VSAN administrative state is 'active', then the 'SET' operation on this object results in error. However to force the value of 'Error Detect Timeout Value', when the VSAN administrative state is 'active', the corresponding instance of 'vsanFcTimerForceFlag' bit position 1 should be set.

This OID is also declared by other modules: CISCO-VSAN-MIB

Details

Reference

Section 29.2.1.2 E_D_TOV in FC-PH (Fibre Channel - Physical and Signaling Interface) Rev 4.3.

Table columns

10 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.282.1.4.8.1.1 vsanFcTimerForceFlag readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.1 vsanFcTimerForceFlag readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.2 vsanFcTimerRatov readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.2 vsanFcTimerRatov readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.3 vsanFcTimerEdtov readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.3 vsanFcTimerEdtov readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.4 vsanFcTimerDstov readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.4 vsanFcTimerDstov readwrite Unknown
1.3.6.1.4.1.9.9.282.1.4.8.1.5 vsanFcTimerFstov readonly CiscoMilliSeconds
1.3.6.1.4.1.9.9.282.1.4.8.1.5 vsanFcTimerFstov readonly CiscoMilliSeconds

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.9.282.3.2.12 vsanFcTimerGroupRev1

Comments