cltcTunnelDropThreshold

  • 1.3.6.1.4.1.9.9.246.1.4.1.1.2
  • Access readwrite
  • Type Unsigned32
  • Unit PDUs/sec

The drop threshold on an interface for a given protocol. After reaching this drop threshold, the interface will start dropping PDUs for the given protocol. This value cannot be greater than the value of cltcTunnelShutdownThreshold. A value of 0 indicates that no limit is set.

This OID is also declared by other modules: CISCO-L2-TUNNEL-CONFIG-MIB

Table columns

6 objects
Oid Name Access Type
1.3.6.1.4.1.9.9.246.1.4.1.1.1 cltcTunnelThresholdProtocolIndex noaccess all(1), cdp(2), vtp(3), stp(4), eoam(5)
1.3.6.1.4.1.9.9.246.1.4.1.1.1 cltcTunnelThresholdProtocolIndex noaccess all(1), cdp(2), vtp(3), stp(4), eoam(5), lldp(6)
1.3.6.1.4.1.9.9.246.1.4.1.1.2 cltcTunnelDropThreshold readwrite Unsigned32
1.3.6.1.4.1.9.9.246.1.4.1.1.2 cltcTunnelDropThreshold readwrite Unsigned32
1.3.6.1.4.1.9.9.246.1.4.1.1.3 cltcTunnelShutdownThreshold readwrite Unsigned32
1.3.6.1.4.1.9.9.246.1.4.1.1.3 cltcTunnelShutdownThreshold readwrite Unsigned32

Used by notifications

1 objects
  • 1.3.6.1.4.1.9.9.246.2.0.1 cltcTunnelDropThresholdExceeded

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.9.246.3.2.3 cltcTunnelThresholdGroup