cds1AlarmThreshold
The value set in this object determines the value that the alarm integration counter must reach for an near end alarm to be declared. If the up count is 6, and the threshold 150, an Alarm is integrated in 2.5 seconds. If the down count is 1, then alarm will be cleared in 15 seconds.
This OID is also declared by other modules:
CISCO-DS1-EXT-MIB
Table columns
12 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.4.1.9.9.229.1.2.2.1.1 | cds1StatisticalAlarmSeverity | readwrite | minor(1), major(2), none(3) |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.1 | cds1StatisticalAlarmSeverity | readwrite | minor(1), major(2), none(3) |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.2 | cds1StatisticalAlarmState | readonly | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.2 | cds1StatisticalAlarmState | readonly | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.3 | cds1AlarmUpCount | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.3 | cds1AlarmUpCount | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.4 | cds1AlarmDownCount | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.4 | cds1AlarmDownCount | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.5 | cds1AlarmThreshold | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.5 | cds1AlarmThreshold | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.6 | cds1AlarmThresholdActiveGroup | readwrite | Unknown |
| 1.3.6.1.4.1.9.9.229.1.2.2.1.6 | cds1AlarmThresholdActiveGroup | readwrite | Unknown |
Used by conformance groups
1 objects- 1.3.6.1.4.1.9.9.229.3.2.6 ciscoDs1AlarmConfigGroup