tmnxChassisPowerSupplyOutputStatus
If the value of tmnxChassisPowerSupplyOutputStatus is 'deviceStateOk', the output voltage of the power supply is within range. If the value is 'deviceStateFailed', an output voltage out of range condition has been detected. A value of 'deviceNotEquipped' indicates that the power supply is not present.
This OID is also declared by other modules:
TIMETRA-CHASSIS-MIB
Details
Possible values
| 1 | deviceStateUnknown |
| 2 | deviceNotEquipped |
| 3 | deviceStateOk |
| 4 | deviceStateFailed |
| 5 | deviceStateOutOfService |
Table columns
10 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.1 | tmnxChassisPowerSupplyId | noaccess | Unknown |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.2 | tmnxChassisPowerSupplyACStatus | readonly | TmnxDeviceState |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.3 | tmnxChassisPowerSupplyDCStatus | readonly | TmnxDeviceState |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.4 | tmnxChassisPowerSupplyTempStatus | readonly | TmnxDeviceState |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.5 | tmnxChassisPowerSupplyTempThreshold | readonly | Integer32 |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.6 | tmnxChassisPowerSupply1Status | readonly | TmnxDeviceState |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.7 | tmnxChassisPowerSupply2Status | readonly | TmnxDeviceState |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.8 | tmnxChassisPowerSupplyAssignedType | readwrite | none(0), dc(1), acSingle(2), acMultiple(3) |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.9 | tmnxChassisPowerSupplyInputStatus | readonly | TmnxDeviceState |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.10 | tmnxChassisPowerSupplyOutputStatus | readonly | TmnxDeviceState |
Used by notifications
1 objects- 1.3.6.1.4.1.6527.3.1.3.2.1.0.3 tmnxEqPowerSupplyFailure
Used by conformance groups
1 objects- 1.3.6.1.4.1.6527.3.1.1.2.1.2.15 tmnx7710HwV3v0Group