etsysLinkFlapIntfDownTime

  • 1.3.6.1.4.1.5624.1.2.52.1.2.1.1.7
  • Access readwrite
  • Type Unknown
  • Unit seconds
  • Default 300

The time period during which the violating interface operational status may be held to 'down' by the LinkFlap functionality. Note that one special value, 0 (zero) of the etsysLinkFlapIntfDownTime is used to specify that etsysLinkFlapIntfDownTime is unbounded. Maintaining the value of this object across agent reboots is REQUIRED

Table columns

11 objects
Oid Name Access Type
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.1 etsysLinkFlapIntfEnabledStatus readwrite enabled(1), disabled(2)
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.2 etsysLinkFlapIntfAction readwrite LinkFlapIntfAction
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.3 etsysLinkFlapIntfOperStatus readwrite operational(1), disabled(2)
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.4 etsysLinkFlapIntfClearStats readwrite TruthValue
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.5 etsysLinkFlapIntfCountThreshold readwrite Unsigned32
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.6 etsysLinkFlapIntfTimeInterval readwrite Unknown
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.7 etsysLinkFlapIntfDownTime readwrite Unknown
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.8 etsysLinkFlapIntfLinkdownCountCurrent readonly Gauge32
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.9 etsysLinkFlapIntfLinkdownCountTotal readonly Gauge32
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.10 etsysLinkFlapIntfCurrentElapsed readonly Unsigned32
1.3.6.1.4.1.5624.1.2.52.1.2.1.1.11 etsysLinkFlapIntfLinkFlapViolations readonly Gauge32

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.5624.1.2.52.2.1.2 etsysLinkFlapInterfaceGroup

Comments