etsysPsePortDetectionStatus

  • 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.6
  • Access readonly
  • Type disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6), requestingPower(7)

Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of deliveringPower(3) - indicates that the PSE State diagram is in the state POWER_ON for a duration greater than tlim max. A value of fault(4) - indicates that the PSE State diagram is in the state TEST_ERROR. A value of test(5) - indicates that the PSE State diagram is in the state TEST_MODE. A value of otherFault(6) - indicates that the PSE State diagram is in the state IDLE due to the variable error_conditions. A value of searching(2)- indicates the PSE State diagram is in a state other than those listed above. A value of requestingPower(7) - indicates the PSE State diagram is in the state IDLE after transitioning from the state POWER_DENIED due to insufficient PSE power being available to satisfy the PD's requirements.

Details

Possible values
1 disabled
2 searching
3 deliveringPower
4 fault
5 test
6 otherFault
7 requestingPower

Table columns

6 objects
Oid Name Access Type
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1 etsysPsePortPowerLimit readwrite Unknown
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.2 etsysPsePortPowerUsage readonly Gauge32
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.3 etsysPsePortPDType readonly legacy(1), ieee8023af(2), other(3), ieee8023(4), ieee8023at(5)
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.4 etsysPsePortCapability readonly Unknown
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.5 etsysPsePortCapabilitySelect readwrite ieee8023af(1), ieee8023at(2)
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.6 etsysPsePortDetectionStatus readonly disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6), requestingPower(7)

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.5624.1.2.50.2.1.6 etsysPsePortPowerManagementGroupRev2

Comments