juniSonetMediumLoopbackConfig

  • 1.3.6.1.4.1.4874.2.2.7.1.1.1.2
  • Access readwrite
  • Type sonetNoLoop(0), sonetFacilityLoop(1), sonetTerminalLoop(2), sonetOtherLoop(3)

The current loopback state of the SONET/SDH interface. The values mean: sonetNoLoop Not in the loopback state. A device that is not capable of performing a loopback on this interface shall always return this value. sonetFacilityLoop The received signal at this interface is looped back out through the corresponding transmitter in the return direction. sonetTerminalLoop The signal that is about to be transmitted is connected to the associated incoming receiver. sonetOtherLoop Loopbacks that are not defined here.

This OID is also declared by other modules: Unisphere-Data-SONET-MIB

Details

Possible values
0 sonetNoLoop
1 sonetFacilityLoop
2 sonetTerminalLoop
3 sonetOtherLoop

Table columns

6 objects
Oid Name Access Type
1.3.6.1.4.1.4874.2.2.7.1.1.1.1 juniSonetMediumType readwrite sonet(1), sdh(2)
1.3.6.1.4.1.4874.2.2.7.1.1.1.2 juniSonetMediumLoopbackConfig readwrite sonetNoLoop(0), sonetFacilityLoop(1), sonetTerminalLoop(2), sonetOtherLoop(3)
1.3.6.1.4.1.4874.2.2.7.1.1.1.3 juniSonetMediumTimingSource readwrite loop(0), internalModule(1), internalChassis(2)
1.3.6.1.4.1.4874.2.2.7.1.1.1.4 juniSonetMediumCircuitIdentifier readwrite DisplayString
1.3.6.1.4.1.4874.2.2.7.1.1.1.5 juniSonetMediumTriggerAlarms readonly Unknown
1.3.6.1.4.1.4874.2.2.7.1.1.1.6 juniSonetMediumTriggerDelay readwrite Unknown

Used by conformance groups

3 objects
  • 1.3.6.1.4.1.4874.2.2.7.4.2.1 juniSonetGroup
  • 1.3.6.1.4.1.4874.2.2.7.4.2.4 juniSonetGroup2
  • 1.3.6.1.4.1.4874.2.2.7.4.2.8 juniSonetGroup3