juniSystemUtilizationThresholdFalling

  • 1.3.6.1.4.1.4874.2.2.2.1.10.1.1.8
  • Access readwrite
  • Type Gauge32

The threshold value (fallingVal), which, in conjunction with juniSystemUtilizationHoldDownTime (holdTime) and juniSystemUtilizationThresholdRising (risingVal), is used to decide when to trigger an event indicating that the resource utilization, juniSystemUtilizationCurrentValue (currentVal), has fallen to or below this level after having exceeded this value. See the DESCRIPTION for juniSystemUtilizationResourceSubType for what constitutes a unit of value for this object. The value of this object must be less than the value of risingVal. This object provides one element in the formula used to determine when to send a utilization notification. If the currentVal falls to equal the fallingVal and no other utilization event (either rising or falling) has been triggered within the holdTime, or if the holdTime for a rising threshold notification expires and the currentVal is at or below the fallingVal, then and only then is a falling threshold utilization notification sent. The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION states the algorithm more precisely.

Table columns

9 objects
Oid Name Access Type
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.1 juniSystemUtilizationResourceType noaccess interface(1), memory(2)
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.2 juniSystemUtilizationResourceSubType noaccess Unknown
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.3 juniSystemUtilizationLocationType noaccess JuniSystemLocationType
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.4 juniSystemUtilizationLocation noaccess JuniSystemLocation
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.5 juniSystemUtilizationMaxCapacity readonly Gauge32
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.6 juniSystemUtilizationCurrentValue readonly Gauge32
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.7 juniSystemUtilizationThresholdRising readwrite Gauge32
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.8 juniSystemUtilizationThresholdFalling readwrite Gauge32
1.3.6.1.4.1.4874.2.2.2.1.10.1.1.9 juniSystemUtilizationHoldDownTime readwrite Gauge32

Used by notifications

1 objects
  • 1.3.6.1.4.1.4874.2.2.2.0.9 juniSystemUtilizationThreshold

Used by conformance groups

2 objects
  • 1.3.6.1.4.1.4874.2.2.2.2.2.12 juniSystemUtilizationGroup
  • 1.3.6.1.4.1.4874.2.2.2.2.2.16 juniSystemUtilizationGroup2

Comments