juniERXSysTimingSourceLine

deprecated

The line type timing source for this entry. The juniRxSysTimingSourceType object must be set to timingLine(3) for the agent to accept a set to this object.

This OID is also declared by other modules: Unisphere-Data-ERX-System-MIB

Details

Possible values
0 timingSourceLineUndefined
1 timingSourceLineE1PortA
2 timingSourceLineE1PortB
3 timingSourceLineT1PortA
4 timingSourceLineT1PortB

Table columns

5 objects
Oid Name Access Type
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.1 juniERXSysTimingSelectorIndex noaccess JuniTimingSelector
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.2 juniERXSysTimingSourceType readwrite JuniTimingSourceType
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.3 juniERXSysTimingSourceIfIndex readwrite InterfaceIndexOrZero
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.4 juniERXSysTimingSourceLine readwrite JuniTimingSourceLineType
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.5 juniERXSysTimingStatus readonly timingStatusOk(1), timingStatusError(2), timingStatusUnknown(3)

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.4874.2.2.17.2.2.11 juniERXSysTimingGroup

Comments