coDot11OperatingMode

  • 1.3.6.1.4.1.12394.1.10.5.4.3.1.1.8
  • Access readwrite
  • Type accessPointAndWirelessLinks(1), accessPointOnly(2), wirelessLinksOnly(3), monitor(4)

Operating mode of the radio. Available options are: Access point and Wireless links: Standard operating mode provides support for all wireless functions. Access point only: Only provides access point functionality, wireless links cannot be created. Wireless links only: Only provides wireless links functionality. Wireless client stations cannot connect. Monitor: Enables the radio to be used for monitoring (wireless neighborhood) only. Both access point and wireless links functionality are disabled.

Details

Possible values
1 accessPointAndWirelessLinks
2 accessPointOnly
3 wirelessLinksOnly
4 monitor

Table columns

12 objects
Oid Name Access Type
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.1 coDot11PHYType readonly fhss(1), dsss(2), irbaseband(3), ofdm(4)
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.2 coDot11CurrentRegDomain readonly Integer32
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.3 coDot11TempType readonly tempType1(1), tempType2(2)
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.4 coDot11CurrentOperFrequency readonly Unsigned32
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.5 coDot11CurrentOperPHYType readonly ieee802dot11a(1), ieee802dot11b(2), ieee802dot11g(3), ieee802dot11bAndg(4)
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.6 coDot11Sensitivity readwrite large(1), medium(2), small(3)
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.7 coDot11RadioEnabled readwrite TruthValue
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.8 coDot11OperatingMode readwrite accessPointAndWirelessLinks(1), accessPointOnly(2), wirelessLinksOnly(3), monitor(4)
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.9 coDot11AutoChannelEnabled readwrite TruthValue
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.10 coDot11AutoChannelInterval readwrite disable(0), timeOfDay(1), oneHour(60), twoHours(120), fourHours(240), eightHours(480), twelveHours(720), tweentyFourHours(1440)
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.11 coDot11AutoPowerEnabled readwrite TruthValue
1.3.6.1.4.1.12394.1.10.5.4.3.1.1.12 coDot11AutoPowerInterval readwrite oneHour(60), twoHours(120), fourHours(240), eightHours(480), twelveHours(720), tweentyFourHours(1440)

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.12394.1.10.5.4.6.1.6 coDot11PhyConfigComplianceGroup