icfVgRptrDetectedDupAddress

  • 1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.3
  • Access readonly
  • Type TruthValue

This object is used to indicate that the repeater detected an error-free training frame on this port with a source MAC address which matches the value of icfVgAddrLastTrainedAddress of another active port. This is reset to 'false' when an error-free training frame is received with a source MAC address which does not match icfVgAddrLastTrainedAddress of another port which is active. For the cascade port, this object will be 'true' if the 'D' bit in the most recently received error-free training response frame was set.

This OID is also declared by other modules: ICF-VG-RPTR

Details

Reference

IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, 13.2.4.5.1, aLocalRptrDetectedDupAddr.

Table columns

8 objects
Oid Name Access Type
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.1 icfVgAddrLastTrainedAddress readonly Unknown
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.1 icfVgAddrLastTrainedAddress readonly Unknown
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.2 icfVgAddrTrainedAddrChanges readonly Counter32
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.2 icfVgAddrTrainedAddrChanges readonly Counter32
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.3 icfVgRptrDetectedDupAddress readonly TruthValue
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.3 icfVgRptrDetectedDupAddress readonly TruthValue
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.4 icfVgMgrDetectedDupAddress readwrite TruthValue
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.4 icfVgMgrDetectedDupAddress readwrite TruthValue

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.11.2.14.10.2.10.1.2.5 icfVgRptrAddrTrackGroup

Comments