hpicfPsePowerRedundancy
This object is used to configure the POE power redundancy mode for this power source equipment. A value of none(1) - means that all available power can be allocated to powered devices. A value of nPlus1(2) - means that one of the highest power supplies is held in reserve and that in the event of a single power supply failure, no powered devices will be shut down. A value of full(3) - means that half of the available power supplies are held in reserve. The default value is none(1).
Details
Possible values
| 1 | none |
| 2 | nPlus1 |
| 3 | full |
Table columns
7 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.1 | hpicfPseAllowPreStdDetect | readwrite | TruthValue |
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.2 | hpicfPsePowerRedundancy | readwrite | none(1), nPlus1(2), full(3) |
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.3 | hpicfPseExtPwrSupplyCount | readwrite | Unknown |
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.4 | hpicfPseAvailablePower | readonly | Unknown |
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.5 | hpicfPseUsedPower | readonly | Unknown |
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.6 | hpicfPseFailoverPower | readonly | Unknown |
| 1.3.6.1.4.1.11.2.14.11.1.9.1.6.1.7 | hpicfPseRedundantPower | readonly | Unknown |
Used by conformance groups
1 objects- 1.3.6.1.4.1.11.2.14.11.1.9.1.2.2.3 hpicfPseFeaturesGroup