serialConnectType
deprecatedThe type of outgoing connection to be made. If this object has the value direct(1), then a direct serial connection is assumed. If this object has the value modem(2), then serialConnectDialString will be used to make a modem connection. If this object has the value switch(3), then serialConnectSwitchConnectSeq will be used to establish the connection over a serial data switch, and serialConnectSwitchDisconnectSeq will be used to terminate the connection. If this object has the value modem-switch(4), then a modem connection will be made first, followed by the switch connection. This object may not be modified if the associated serialConnectStatus object is equal to active(1).
Details
| 1 | direct |
| 2 | modem |
| 3 | switch |
| 4 | modemSwitch |
Table columns
9 objects| Oid | Name | Access | Type |
|---|---|---|---|
| 1.3.6.1.2.1.16.19.14.1.1 | serialConnectIndex | noaccess | Unknown |
| 1.3.6.1.2.1.16.19.14.1.2 | serialConnectDestIpAddress | readwrite | IpAddress |
| 1.3.6.1.2.1.16.19.14.1.3 | serialConnectType | readwrite | direct(1), modem(2), switch(3), modemSwitch(4) |
| 1.3.6.1.2.1.16.19.14.1.4 | serialConnectDialString | readwrite | Unknown |
| 1.3.6.1.2.1.16.19.14.1.5 | serialConnectSwitchConnectSeq | readwrite | Unknown |
| 1.3.6.1.2.1.16.19.14.1.6 | serialConnectSwitchDisconnectSeq | readwrite | Unknown |
| 1.3.6.1.2.1.16.19.14.1.7 | serialConnectSwitchResetSeq | readwrite | Unknown |
| 1.3.6.1.2.1.16.19.14.1.8 | serialConnectOwner | readwrite | OwnerString |
| 1.3.6.1.2.1.16.19.14.1.9 | serialConnectStatus | readwrite | RowStatus |
Used by conformance groups
1 objects- 1.3.6.1.2.1.16.20.2.10 probeConfigurationGroup