pethPsePortPowerPriority

  • 1.3.6.1.2.1.105.1.1.1.7
  • Access readwrite
  • Type critical(1), high(2), low(3)

This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority.

Details

Possible values
1 critical
2 high
3 low

Table columns

14 objects
Oid Name Access Type
1.3.6.1.2.1.105.1.1.1.1 pethPsePortGroupIndex noaccess Unknown
1.3.6.1.2.1.105.1.1.1.2 pethPsePortIndex noaccess Unknown
1.3.6.1.2.1.105.1.1.1.3 pethPsePortAdminEnable readwrite TruthValue
1.3.6.1.2.1.105.1.1.1.4 pethPsePortPowerPairsControlAbility readonly TruthValue
1.3.6.1.2.1.105.1.1.1.5 pethPsePortPowerPairs readwrite signal(1), spare(2)
1.3.6.1.2.1.105.1.1.1.6 pethPsePortDetectionStatus readonly disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6)
1.3.6.1.2.1.105.1.1.1.7 pethPsePortPowerPriority readwrite critical(1), high(2), low(3)
1.3.6.1.2.1.105.1.1.1.8 pethPsePortMPSAbsentCounter readonly Counter32
1.3.6.1.2.1.105.1.1.1.9 pethPsePortType readwrite SnmpAdminString
1.3.6.1.2.1.105.1.1.1.10 pethPsePortPowerClassifications readonly class0(1), class1(2), class2(3), class3(4), class4(5)
1.3.6.1.2.1.105.1.1.1.11 pethPsePortInvalidSignatureCounter readonly Counter32
1.3.6.1.2.1.105.1.1.1.12 pethPsePortPowerDeniedCounter readonly Counter32
1.3.6.1.2.1.105.1.1.1.13 pethPsePortOverLoadCounter readonly Counter32
1.3.6.1.2.1.105.1.1.1.14 pethPsePortShortCounter readonly Counter32