This object indicates the revertive mode
setting in the G.781 clock selection process.
The switching of clock sources can be made revertive or
non-revertive. In non-revertive mode, an alternate
clock source is maintained even after the original clock
source has recovered from the failure that caused the switch.
In revertive mode, the clock selection process switches back
to the original clock source after recovering from the
failure.