This object is used in conjunction with
'clrPeerHeartBeatTime' to switch over the active
redundancy unit or not. Switch over occurs if
heartbeats are not received from the peer
during a specific time period, which
is equal to ( clrPeerHeartBeatTime *
clrPeerHeartBeatCount ) .