The value of the object tTodNotifSuiteParmsFltrOrPlcyId indicates the
filter-id involved in the time-based control.
This object is meaningful only if tTodNotifSuiteParmsApplicObj
is set to one of the following values.
ingressIpFilter (0)
ingressIPv6Filter (1)
ingressMacFilter (2)
ingressQosPlcy (3)
egressIpFilter (5)
egressIPv6Filter (6)
egressMacFilter (7)
egressQosPlcy (8)
In all other cases the value of this object is meaningless.