The value of tVrrpOpMasterDownTimer indicates the current
value of the Master Down Timer in milliseconds.
When a backup router receives a VRRP advertisement from a master,
it resets this timer to the value of the Master Down Interval
and begins to count down. If the backup router does not receive
an advertisement till this timer times out, it will assume that
the master is down and will declare itself to be the master.