This object allows entries to be created and deleted
in the tmnxOamSaaCtlTable. Deletion of an entry in this
table results in all corresponding control and results entries
in either the ping or traceroute tables.
Activation of a Alcatel-Lucent SROS OAM ping or trace route operation
is controlled via tmnxOamPingCtlAdminStatus or
tmnxOamTrCtlAdminStatus and not by changing this object's value
to 'active (1)'.
An attempt to delete an entry in this table by setting this object's
value to 'destroy (6)' will fail with an inconsistentValue error
if the associated ping or traceroute test is in progress.
An attempt to delete an entry in this table by setting this object's
value to 'destroy (6)' will fail with an inconsistentValue error
if the value of tmnxOamSaaCtlAdminStatus is not 'outOfService'.
The operational state of an Alcatel-Lucent SROS OAM SAA test operation
can be determined by examination of its associated
tmnxOamPingResultsOperStatus or tmnxOamTrResultsOperStatus object.