The value of tmnxOamTrCtlInterval specifies the number of seconds
to wait before repeating an Alcatel-Lucent SROS OAM Trace Route test as
defined by the value of the various objects in the corresponding row.
This parameter is optional.
The number of hops in a single Alcatel-Lucent SROS OAM Trace Route test
is determined by the value of the corresponding
tmnxOamTrCtlProbesPerHop object. After a single test completes,
the number of seconds as defined by the value of tmnxOamTrCtlInterval
MUST elapse before the next Alcatel-Lucent SROS OAM Trace Route test is
started.
The applicability, range, and default value of this object vary with
tmnxOamTrCtlTestMode, as shown in the following table.
tmnxOamTrCtlTestMode Min Max Default
'ethCfmLinkTrace' 1 10 5
'icmpTraceRoute' not applicable
'vccvTraceRoute' 1 255 1
otherwise 1 10 1