tmnxOamTrCtlInterval 1.3.6.1.4.1.6527.3.1.2.11.2.3.1.19

The value of tmnxOamTrCtlInterval specifies the number of seconds to wait before repeating an Alcatel-Lucent SROS OAM Trace Route test as defined by the value of the various objects in the corresponding row. This parameter is optional. The number of hops in a single Alcatel-Lucent SROS OAM Trace Route test is determined by the value of the corresponding tmnxOamTrCtlProbesPerHop object. After a single test completes, the number of seconds as defined by the value of tmnxOamTrCtlInterval MUST elapse before the next Alcatel-Lucent SROS OAM Trace Route test is started. The applicability, range, and default value of this object vary with tmnxOamTrCtlTestMode, as shown in the following table. tmnxOamTrCtlTestMode Min Max Default 'ethCfmLinkTrace' 1 10 5 'icmpTraceRoute' not applicable 'vccvTraceRoute' 1 255 1 otherwise 1 10 1

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.6527.3.1.2.11.2.3.1 tmnxOamTrCtlEntry