The value of tmnxOamTrCtlMaxFailures specifies the maximum number of
consecutive timeouts allowed before terminating a trace route test.
This object is optional.
As shown in the following table
a) this object is applicable to a subset of the test types, and
b) the default value and upper bound depend on the test type.
tmnxOamTrCtlTestMode Applicable? Default Upper Bound
-------------------- ----------- ------- -----------
'icmpTraceRoute' yes 90 90
'lspTraceRoute' yes 5 255
'p2mpLspTrace' yes 5 10
'vccvTraceRoute' yes 5 255
otherwise no N/A N/A
In the 'icmpTraceRoute' case, changing the tmnxOamTrCtlMaxFailures
value away from the default is not supported.