tmnxOamLspPingCtlTestSubMode 1.3.6.1.4.1.6527.3.1.2.11.1.9.1.16

The value of tmnxOamLspPingCtlTestSubMode specifies the type of LSP ping test to perform. When this object is 'unspecified(1)', the type of LSP ping test to be performed is determined when the test is started, from the set of tmnxOamLspPingCtlTable objects configured with non-default values. If there is a mismatch between tmnxOamLspPingCtlTestSubMode and the type of the LSP to be tested, the test will fail. For example, if tmnxOamLspPingCtlTestSubMode is 'static(2)', and tmnxOamLspPingCtlLspName refers to an LSP with TIMETRA-MPLS-MIB::vRtrMplsLspType not equal to 'mplsTp(7)', the test will fail. The supported object combinations for LSP ping tests are listed in the tmnxOamLspPingCtlTable DESCRIPTION clause.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.6527.3.1.2.11.1.9.1 tmnxOamLspPingCtlEntry