tmnxOamPingCtlProbeCount
1.3.6.1.4.1.6527.3.1.2.11.1.3.1.22
The value of tmnxOamPingCtlProbeCount specifies the number of probes to
send during the test.
The maximum probe count depends on the value of tmnxOamPingCtlTestMode,
as follows:
'macPopulate', 'macPurge','p2mpLspPing', 'svcPing' : 1
'ethCfmTwoWayDelay', 'ethCfmTwoWaySlm' : 1000
'icmpPing' : 100000
otherwise : 100
For the following tmnxOamPingCtlTestMode values, the value of
tmnxOamPingCtlProbeCount does not affect the behavior of the test:
'mrInfo', 'mtuPing'.
If tmnxOamPingCtlTestMode is 'icmpPing', the default probe count value
is 5. Otherwise, the DEFVAL applies.