h3cDot3OamErrSymPeriodThresholdHi 1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.3

The two objects h3cDot3OamErrSymPeriodThresholdHi and h3cDot3OamErrSymPeriodThresholdLo together form an unsigned 64-bit integer representing the number of symbol errors that must occur within a given window to cause this event. This is defined as h3cDot3OamErrSymPeriodThreshold = ((2^32) * h3cDot3OamErrSymPeriodThresholdHi) + h3cDot3OamErrSymPeriodThresholdLo If h3cDot3OamErrSymPeriodThreshold symbol errors occur within a window of h3cDot3OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating the threshold has been crossed in this window.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1 h3cDot3OamEventConfigEntry