h3cDot3OamErrSymPeriodWindowHi 1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1.1

The two objects h3cDot3OamErrSymPeriodWindowHi and h3cDot3OamErrSymPeriodLo together form an unsigned 64-bit integer representing the number of symbols over which this threshold event is defined. This is defined as h3cDot3OamErrSymPeriodWindow = ((2^32)*h3cDot3OamErrSymPeriodWindowHi) + h3cDot3OamErrSymPeriodWindowLo If h3cDot3OamErrSymPeriodThreshold symbol errors occur within a window of h3cDot3OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating the threshold has been crossed in this window.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.43.45.1.10.2.42.3.1.5.1 h3cDot3OamEventConfigEntry