A port monitor table entry contains information relating a
bridge port being monitored with the address of the analyzer
which is being used to monitor the port.
The effect of creating an entry for a particular port is to
enable monitoring of that port by the analyzer specified. To
create an entry, set the value of the
a3ComSysNetworkPortMonitorAnalyzerAddress object to the address of
the network analyzer port. This value should be the same as
the value of the a3ComSysNetworkAnalyzerPhysicalAddress object for
the analyzer.
The effect of removing an entry for a particular port is to
disable monitoring of that port. To remove an entry, set the
value of the corresponding instance of the
a3ComSysNetworkPortMonitorStatus object to invalid(2).