The Test Boot Time indicates the number of seconds
after a test reboot the system will automatically
reboot. Upon reboot, the system will start up a timer
initialized to the value of this object. The object
a3sysTestRecoveryTimer contains the real time value of
this timer. The timer will automatically start counting
down after the system comes up. If this timer expires,
the system will automatically reboot using the Primary Boot
Source.
To cancel the timer, the object a3sysTestRecoveryTimer must
be set to zero. This provides a recovery mechanism for a
system under test that loses management connectivity.