XcmHrDevMgmtCommandRequest

  • Base type Enumeration

A write of this type by an (authorized) management station invokes a command for this device. A read of this type always returns the command currently in progress or last completed. It is mandatory that a conforming management agent ensure that the contents of this object remain 'in bounds' - an undefined value SHALL be replaced by 'none' - ie, although rejected with error in the SetResponse PDU, this object SHALL NOT contain any such undefined value. At system initialization, this object SHALL contain 'none'. * 'none' - NO action(s) SHALL be taken, except to clear '...CommandData' and set '...CommandStatus' to 'noError'. * 'test' or 'manage' - the associated '...CommandData' object SHOULD/SHALL be specified in the same SetRequest PDU. * all other commands - the associated '...CommandData' object MAY be specified in the same SetRequest PDU. * 'startup', 'resetWarm', 'resetCold', or 'resetFactory' - the final state SHALL be 'running' (after cycle completes) - the sequence of states SHOULD be 'down' -> 'testing' -> 'running' - the final power mode SHALL be 'ready'. * 'startup' - this device SHALL transition from the 'down' state to the 'running' state and 'ready' power mode. * 'resetWarning' - this device SHALL transition from the 'warning' state to the 'running' state (because a management station has acknowledged the management agent's previous warning). * 'test' - this device SHALL transition immediately (ie, without attempting graceful quiesce) to the 'testing' state; it is a local matter (ie, device specific) how this command is processed; however, '...CommandData' SHOULD be specified. * 'shutdown' - this device SHALL transition immediately (ie, without attempting graceful quiesce) to the 'down' state and 'off' power mode. * 'quiesce' - this device MAY transition gracefully to the 'down' state, or it MAY choose to treat a 'quiesce' as 'shutdown'. * 'resetCounters' - all device counters SHALL be reset to zero and the device SHALL remain in the same state and power mode. * 'resetWarm' - a device 'warm restart' SHALL be performed (ie, without a power cycle reset). * 'resetCold' - a device 'cold restart' SHALL be performed (ie, with a power cycle reset). * 'resetFactory' - all factory defaults SHALL be restored, and a device 'cold restart' SHALL be performed (ie, with a power cycle reset). * 'flushInput' - all device input (in progress or internally queued) SHALL be gracefully flushed. * 'flushOutput' - all device output (in progress or internally queued) SHALL be gracefully flushed. * 'flushInOut' - all device input and output output (in progress or internally queued) SHALL be gracefully flushed. * 'manage' - it is a local matter (ie, device specific) how this command is processed; however, '...CommandData' SHALL be specified. * 'refresh' - the device SHALL promptly read all of its manageable configuration parameters, but SHALL NOT perform a reset. * 'warmUp' - the device SHALL transition from the 'standby' mode to the 'ready' mode - invalid from any other power mode (optional command for remote device power management). * 'coolDown' - the device SHALL transition from the 'ready' mode to the 'standby' mode - invalid from any other power mode (optional command for remote device power management). * 'energySave' - the device SHALL transition from the 'standby' mode to the 'sleep' mode - invalid from any other power mode (optional command for remote device power management). * 'wakeUp' - the device SHALL transition from the 'sleep' mode to the 'standby' mode - invalid from any other power mode (optional command for remote device power management). * 'powerToReady' - the device SHALL transition from the 'standby' mode or the 'sleep' mode to the 'ready' mode (optional command for remote device power management). * 'powerToStandby' - the device SHALL transition from the 'ready' mode or the 'sleep' mode to the 'standby' mode (optional command for remote device power management). * 'powerToSleep' - the device SHALL transition from the 'ready' mode or the 'standby' mode to the 'sleep' mode (optional command for remote device power management). Note: All of the POSIX and XCMI device level operations are taken from the POSIX System Admin std (IEEE 1387.4) and aligned with the high-end XCMI System Admin MIB.

Possible values

79 objects
Number Name
1 none
2 startup
3 resetWarning
4 test
5 shutdown
6 quiesce
7 resetCounters
8 resetWarm
9 resetCold
10 resetFactory
11 flushInput
12 flushOutput
13 flushInOut
14 manage
15 refresh
16 warmUp
17 coolDown
18 energySave
19 wakeUp
20 powerToReady
21 powerToStandby
22 powerToSleep
1301 deviceCreate
1302 deviceDelete
1303 deviceList
1304 deviceSet
1305 deviceClean
1306 deviceDisable
1307 deviceEnable
1308 devicePause
1309 deviceResume
1310 deviceShutdown
1311 deviceQueueList
1312 deviceJobCreate
1901 entityCreate
1902 entityDelete
1903 entityList
1904 entitySet
1905 entityClean
1906 entityDisable
1907 entityEnable
1908 entityPause
1909 entityResume
1910 entityShutdown
1911 entityQueueList
1912 entityJobCreate
2301 deviceManage
2302 deviceRestart
2321 deviceInstall
2322 deviceUpgrade
2323 deviceBackup
2324 deviceRestore
2325 deviceConfigure
2326 deviceDiagnose
2331 deviceResetCounters
2332 deviceResetWarm
2333 deviceResetCold
2334 deviceResetFactory
2335 deviceFormat
2336 deviceRefresh
2341 deviceLogin
2342 deviceLogout
2343 deviceDiskOverwrite
2901 entityManage
2902 entityRestart
2921 entityInstall
2922 entityUpgrade
2923 entityBackup
2924 entityRestore
2925 entityConfigure
2926 entityDiagnose
2931 entityResetCounters
2932 entityResetWarm
2933 entityResetCold
2934 entityResetFactory
2935 entityFormat
2936 entityRefresh
2941 entityLogin
2942 entityLogout