CItpTcTimerMtp2T05
Sending SIB timer. The default and valid range is dependant on the value of variant. This timer is only applicable if cItpTcLinkType is serial. A get on this object will return a zero if the link is not serial. Min Max Def ------ ------ ------ ANSI 80 120 80 ITU 80 120 100 The SYNTAX statement allows values for both the ANSI and ITU variants.